Why Is My Haier Freezer Not Cold Enough?

Why Is My Haier Freezer Not Cold Enough?

Haier freezers might not be cooling enough because of problems like defrost system failures, dirty condenser units, fan failures and gaskets for the doors that leak. Although you may notice the cooling issue begin in the freezer, you’ll typically quickly find that the Haier refrigerator and freezer not cooling enough.

It is essential to fix the issue immediately to prevent food loss. How can you prevent air leaks from making your Haier freezer too cold If the Haier freezer is not warm enough to keep the frozen ice cream from becoming too firm or you notice a lot frost inside the freezer, warm, humid air could be coming out of the refrigerator. Replace any damaged gaskets, and check the door gaskets. If your gaskets look good but the door is sliding on its hinges or causing gaps between the door gaskets and the cabinet, adjust the hinges of your Haier refrigerator to ensure that the gaskets properly are able to seal the cabinet. If the accumulation of frost is restricted to the freezer’s back wall then the automatic freeze system may have failed. When working properly, the defrost system melts frost off the coils of the evaporator every 8 hours or so to ensure that the air passageways through the evaporator free of obstructions so that the refrigerator and freezer compartments cool properly.

If the automatic defrost system fails, the frost will build up on the evaporator as well as on the back freezer compartment wall. The Haier freezer isn’t cooling properly because of the frost buildup on the evaporator. How to fix other issues that keep your freezer from getting enough cold If you notice that the fan in the evaporator isn’t running when you check for cooling in the freezer compartment. If it isn’t working properly, change the fan. Condenser coils that are dirty can cause freezing problems. Examine the Haier refrigerator for dust and dirt build-up. If the coils are stained, clean the coils. Continue to clean the coils throughout routine Haier refrigerator maintenance. You should check whether the condenser fan is turned on when the freezer doesn’t become sufficiently cold. The condenser won’t cool refrigerant efficiently when the condenser fan does not operate. If the fan stops running when it’s active, replace it. There are repairs that could help solve the issue with your refrigerator. Replacing the Haier refrigerator’s defrost sensors.

The Haier refrigerator’s defrost sensing device, also known as the bi-metal terminator thermostat, trips when the temperature of the refrigerator reaches an optimum temperature. The defrost sensor will trip when it senses that the temperature in the evaporator has been too high and shuts off the heater. The sensor for defrost could fail if it’s not functioning correctly. This could cause frost to build up on the fins of the evaporator and eventually make the freezer and refrigerator not cool as well. To determine if there is continuity, you can use a volt/ohm tester. If there isn’t any continuity at the temperature of 0°F, then it’s time to replace the defrost sensor. Clean the Haier refrigerator’s compressor coils.

Dust-covered Haier refrigerator compressor coils could hinder the refrigerator and freezer from operating efficiently and cooling effectively. Clean the condenser coiled according to your owner’s manual. Before you are able to get access to and clean the coils inside the Haier refrigerator, disconnect the appliance. The majority of Haier refrigerators have the coils located behind the grill on the front. Use a coil brush to cleanse the coils. Replace the Haier refrigerator compressor condenser Fan: This fan is located in the machine compartment of the Haier fridge next to the compressor. It circulates air across the condenser fan coils to cool the refrigerant hot that is coming out of the compressor. The refrigerant gets cooled before it passes through the expansion device into the evaporator. Replace any defective condenser fans.

Repair the Haier refrigerator freezer defrost: To increase the exchange of heat in the Haier refrigerator’s auto defrost is able to melt the evaporator’s frost. The compressor stops and the defrost heating elements turns on. During defrosting the frost melts off of the the evaporator fins. Condensate flows to an evaporator drip tray beneath the evaporator. It then flows through the defrost drain tube to the drain pan close to the compressor’s the machine compartment. The condensate evaporates out of the drain pan prior to the next defrost cycle. If the defrost procedure fails, identify and repair the problem. Replace the Haier fridge evaporator fans: The evaporator mounts on the evaporator assembly. It moves air through the cabinet, and then across the evaporator fins.

Replace the fan in case damaged. The Haier refrigerator’s temperature controller board must be replaced. It is located inside the machine compartment, near the compressor. It’s hidden behind a panel that is located at the rear of the Haier refrigerator. The temperature control board regulates the compressor and other major components of the Haier refrigerator. You can check it by following the instructions in the technical sheet. If the temperature control board isn’t working or isn’t controlling the components correctly, replace it.

Replace the Haier refrigerator’s thermostat for temperature control. The thermostat has sensors that detect the temperature inside the Haier refrigerator. The thermostat that controls temperature regulates the temperature within the cabinet by switching the compressor on or off in accordance with the temperature sensed by the sensor tube. If it fails to sense temperature accurately or fails to turn off the compressor, the temperature control thermostat should be replaced. Replace the Haier fridge thermistor. The thermostat receives temperature information from the thermistor, so a damaged thermistor might provide false information. Replace the Haier refrigerator freeze timer. The motor for the defrost timer runs and moves the control components within the device. When the control contacts in the defrost timer advance into the defrost cycle the compressor ceases to run and the heater turns on for a specific amount of time to melt frozen evaporator fins.

This promotes more efficient heat exchange across the evaporator. After the timer expires the thermostat’s contacts defrost thermostat return to normal cooling for the Haier refrigerator. If the thermostat for defrost stops moving when it is activated, you’ll need to change it. The defrost heater could be stopped from energized by faulty contacts. If this occurs, you should change the timer for defrost heating. The door to the freezer or the refrigerator door. Refrigerator and freezer doors swing on hinges which can be damaged or bent.

Doors can shift as time passes. This can allow warm humid air to pass through the door of the freezer or refrigerator and cause excessive frost, which can lead to the drain tube freezing. Refrigerator repair involves the adjustment or replacement of hinges to make sure that the doors function properly and remain properly aligned. Replace the Haier refrigerator gasket. The gasket attaches on the refrigerator or freezer door panel. It stops air from getting into the cabinet or escaping it when the door is closed. If the gasket is damaged, moist and warm air could leak through the Haier refrigerator’s door, which can lead to excessive cooling and frost issues.

Replace the door seal if it’s damaged or torn. Replace the Haier refrigerator electronic control board: The electronic control board-also called the main control board, or the power control board (PCB)-controls the compressor and the defrost process. It transmits voltage to the fans and compressors when it detects that the refrigerator must be kept cool. To keep track of the temperature inside the refrigerator or freezer the control panel’s electronic circuit also receives signals from temperature sensors. This information can be used to regulate the defrost process. The electronic control boards can usually be checked for any faults to check if they’re functioning properly. The test is different for each model, but the most common test is called the Forced Defrost test.

The instructions on how to run diagnostics in the tech sheet. If your electronic control board isn’t functioning correctly, you may need to replace it. Maintenance routine for Haier refrigerators: Dusty refrigerator coils can cause issues with the refrigerator’s freezer as well as its ability to properly cool and run efficiently. To clean condenser coils, consult the manual for the owner. Before cleaning the coils and getting access to them, disconnect the Haier refrigerator. The majority of refrigerators have coils behind the front grill. By using a coil brush clean the condenser coils. Additional routine maintenance includes changing the water filter, cleaning the dust off the bottom front grille and adjusting the hinges if the doors don’t seal tightly, and emptying water out of the drain pan.